Harvard Apparatus offers a complete Glucose Clamp Infusion System for rats or mice including syringe pumps, swivels, tethers and catheters. Multiple syringe pumps push glucose, insulin and a drug, tracer glucose or other fluids into a 3 or 4-way connector which combines and reaches the animal via one channel of a dual channel swivel. Blood samples are taken manually or with an automated sampler on the second channel. The two-channel VAH simplifies the animal connection and PinPorts can be used to simplify injections or intermittent sampling.
70-4504GC – Pump 11 Elite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method [Request a Quote]
70-4505GC – Pump 11 Elite Infusion/Withdrawal Programmable Dual Syringe Pump with Glucose Clamp Method [Request a Quote]
70-4506GC – Pump 11 Pico Plus Elite Infusion/Withdrawal Programmable Dual Syringe Pump with Glucose Clamp Method [Request a Quote]
70-4507GC – Pump 11 Elite Nanomite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method [Request a Quote]
70-4511GC – Pump 11 Pico Plus Elite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method [Request a Quote]
Pump 11 Elite GC Glucose Clamp Infusion System
Renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies
The Pump 11 Elite Glucose Clamp Infusion System is a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display. The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.
Animal Weight, Concentration, and Dose Rate Programming: Glucose clamp method allows for the user to enter a desired concentration, animal weight, and dose rate into the syringe pump. The Pump 11 Elite uses that information to properly set the infusion rate automatically.
Change Dose Rate While Running: In the Glucose Clamp method, the user has the ability to change the dose rate during infusion. This allows the execution of complex infusion procedures without the need to start and stop the process.
Previous Dose Rate Display: The previous dose rate setting is displayed while the pump is running, which allows for easy monitoring. When the unit is stopped, the last dose rate set and its duration is clearly displayed.
Pump 11 Elite GC – Short Description
The Pump 11 Elite Glucose Clamp Infusion System, is a version of our renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies.
The glucose clamp capabilities provide a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display.
The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.
The Pump 11 Elite Glucose Clamp Infusion System will simplify glucose clamp experiments with the following features.
1) Animal Weight, Concentration, and Dose Rate Programming
Glucose clamp method allows the user to enter in a desired concentration, animal weight, and dose rate in the syringe pump and then uses that information to set the infusion rate automatically.
2) Change Dose Rate While Running in the Glucose Clamp method
The user has the ability to change the dose rate during infusion. This allows the execution of complex infusion procedures without the need to start and stop the process.
3) Previous Dose Rate Display
The previous dose rate setting is displayed while the pump is running, which allows for easy monitoring. When the unit is stopped, the last dose rate set and its duration is clearly displayed.
Pump 11 Elite GC – Item Listing
Item#
Description
Pricing
70-4504GC
Pump 11 Elite Infusion/Withdrawal Programmable Single Syringe Pump with Glucose Clamp Method
The Pump 11 Elite Glucose Clamp Infusion System, is a version of our renowned syringe pump technology enhanced for academic euglycemic or hyperglycemic glucose clamp studies.
The glucose clamp capabilities provide a time saving syringe pump enhancement that offers quick and simple set-up using our innovative touch screen display. The built-in software capabilities reduce the potential for error in your research by providing the most accurate fluid delivery available.
Features:
Intuitive Touch Screen with Glucose Clamp software
Program animal weight, concentration and dose rate without a PC
Ability to change dose rate while running
Previous dose rate display to simplify data recording
Icon operation
New color LCD touch screen
Vertical or horizontal orientation
Adjustable linear force to 11 or 35 lbs (depending on model) across the entire flow range
CE, ETL (UL, CSA), WEEE, EU RoHS, CB Scheme Approved
2-year warranty Applications:
Euglycemic and hyperglycemic glucose clamp studies
Drug/Nutritional infusions
The Pump 11 Elite Glucose Clamp Infusion System will simplify glucose clamp experiments with the following capabilities:
1) Animal Weight, Concentration, and Dose Rate Programming
Glucose clamp method allows the user to enter in a desired concentration, animal weight, and dose rate in the syringe pump and then uses that information to set the infusion rate automatically.
2) Change Dose Rate While Running in the Glucose Clamp method
The user has the ability to change the dose rate during infusion. This allows the execution of complex infusion procedures without the need to start and stop the process.
3) Previous Dose Rate Display
The previous dose rate setting is displayed while the pump is running, which allows for easy monitoring. When the unit is stopped, the last dose rate set and its duration is clearly displayed.
Pump 11 Elite GC – Specifications
Specifications
70-4504GC
70-4505GC
70-4506GC
70-4507GC
70-4511GC
Accuracy
±0.5%
±0.5%
±0.35%
±0.5%
±0.35%
Syringes
1
2
2
1
1
Flow Rate Minimum
1.26 pl/min
1.26 pl/min
0.54 pl/min
3.66 pl/min
0.54 pl/min
Flow Rate Maximum
88.4 ml/min
26.02 ml/min
11.7 ml/min
3.818 ml/min
39.77 ml/min
Classification
Class I
Class I
Class I
Class I
Class I
Dimensions Control Box LxDxH in cm
9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0)
9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0)
9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0)
9.0 x 7.0 x 3.67 (22.6 x 17.78 x 9.32)
9.0 x 7.0 x 6.0 (22.6 x 17.78 x 15.0)
Dimensions Remote Box LxDxH in cm
N/A
N/A
N/A
2.5 x 2.0 x 7.5 (6.35 x 5.08 x 19.05)
N/A
Display
4.3″ WQVGA TFT Color Display with Touchpad
4.3″ WQVGA TFT Color Display with Touchpad
4.3″ WQVGA TFT Color Display with Touchpad
4.3″ WQVGA TFT Color Display with Touchpad
4.3″ WQVGA TFT Color Display with Touchpad
Drive Motor
0.9° Stepper Motor
0.9° Stepper Motor
0.9° Stepper Motor
1.8° Stepper Motor
0.9° Stepper Motor
Environmental Humidity
20% to 80% RH, non condensing
20% to 80% RH, non condensing
20% to 80% RH, non condensing
20% to 80% RH, non condensing
20% to 80% RH, non condensing
Environmental Operating Temperature English
40°F to 104°F
40°F to 104°F
40°F to 104°F
40°F to 104°F
40°F to 104°F
Environmental Operating Temperature Metric
4°C to 40°C
4°C to 40°C
4°C to 40°C
4°C to 40°C
4°C to 40°C
Environmental Storage Temperatue English
14°F to 158°F
14°F to 158°F
14°F to 158°F
14°F to 158°F
14°F to 158°F
Environmental Storage Temperatue Metric
-10°C to 70°C
-10°C to 70°C
-10°C to 70°C
-10°C to 70°C
-10°C to 70°C
I O TTL Connectors
15 pin D-Sub Connector
15 pin D-Sub Connector
15 pin D-Sub Connector
15 pin D-Sub Connector
15 pin D-Sub Connector
Input Power
12-30 VDC
12-30 VDC
12-30 VDC
12-30 VDC
12-30 VDC
Installation Category
II
II
II
II
II
Max Linear Force
35 lbs at 100% Force
35 lbs at 100% Force
35 lbs at 100% Force
11 lbs at 100% Force
35 lbs at 100% Force
Mode of Operation
Glucose Clamp
Glucose Clamp
Glucose Clamp
Glucose Clamp
Glucose Clamp
Motor Drive Control
Microprocessor with 1/16 microstepping
Microprocessor with 1/16 microstepping
Microprocessor with 1/16 microstepping
Microprocessor with 1/16 microstepping
Microprocessor with 1/16 microstepping
Net Weight English
4.6 lb
4.6 lb
4.6 lb
Control Box (4.32 lb)
Remote Mechanism (1.01 lb)
4.6 lb
Net Weight Metric
2.1 kg
2.1 kg
2.1 kg
Control Box (1.96 kg)
Remote Mechanism (0.458 kg)
2.1 kg
No of Syringes
1
2
2
1
2
Non Volatile Memory
Storage of all settings
Storage of all settings
Storage of all settings
Storage of all settings
Storage of all settings
Number of Microsteps per one rev of Lead Screw
15,360
15,360
20,480
3,200
20,480
Pollution Degree
1
1
1
1
1
Pump Configuration
Single
Dual
Dual
Single
Dual
Pump Function
Infuse/Withdraw, Programmable with Glucose Clamp Method
Infuse/Withdraw, Programmable with Glucose Clamp Method
Infuse/Withdraw, Programmable with Glucose Clamp Method
Infuse/Withdraw, Programmable with Glucose Clamp Method
Infuse/Withdraw, Programmable with Glucose Clamp Method
Harvard Apparatus Pump 11 Elite GC: Intuitive Touch Screen with Glucose Clamp Software – Program Animal Weight, Concentration and Dose Rate Without a PC – Ability to Change Dose Rate While Running Previous Dose Rate Display to Simplify Data Recording
Save this product for later
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.OkPrivacy policy